The AT400 and TAT420 air velocity transmitters supply accurate air velocity and (TAT420) temperature data from a building or process airflow on a continuous basis to a computer, chart recorder, printer and meter or control circuit.
The THT500 humidity-temperature transmitters supply accurate humidity and temperature data from a room or process air source on a continuous basis to a computer, chart recorder, printer, meter or control circuit.
Every instrument has terminals for both DC and AC power and 0-1 V, 0-5V and 4-20mA output.
Navigate the tab section below to see this product’s Features & Benefits, Specifications, Resources, and more.
Main Unit Specifications | ||
---|---|---|
Measurement Specifications | ||
Air Velocity | Metal rotating vane | AP275/APT275: 2.75″ diameter AP100/APT100: 1″ diameter |
Range | 1″ Probe: 300 to 6890 FPM (1.5 to 35 m/s) 2.75″ Probe: 50 to 7800 FPM (0.2 to 40 m/s) |
|
Accuracy | 1″ Probe: ±0.5% of Full-scale + 0.75% of READING ±1 digit 2.75″ Probe: ±1.0% of READING ±1 digit |
|
Resolution | 1 FPM or 0.01 m/s | |
Temperature | Range | APT Probe: -4 to 176 F (-20 to 80C) |
Accuracy | ±0.5°C | |
Resolution | 0.1°F or 0.1°C | |
General Specifications | ||
Analog Output | Current output: DC 4~20mA Voltage output: DC 0~1V or 0~5V |
|
Operating Temperature | Transmitter: -4 to 176F (-20 to 80°C) Probe: -22 to 212F (-30 to 100°C) |
|
Power Supply | 120 or 220 VAC (50-60 Hz) 10 to 30 VDC |
|
Dimensions | Transmitter Housing | W 4.8 x D 2.2 x H 4.8 inches (12.2 x 5.6 x 12.2 cm) |
Warranty | 1 year | 1 x Rotating Vane Probe Head, Probe cable, Operation Manual, NIST Certificate |
TAT420 | 1 x Rotating Vane Probe Head, Probe cable, Operation Manual, NIST Certificate |
Yes, all our instruments come with a calibration certificate.
Annual calibration is recommended to ensure accuracy. However, this can vary based on how often the anemometer is used and the environments it’s used in. Also, some companies have an SOP in place that specifies how often the instrument will need to be serviced. More specifically, regulatory compliance may dictate the calibration interval.
No, these are thermal anemometers that generate heat when in operation; if you expose them to a flammable gas it could cause a fire or explosion. Corrosive or caustic gases, such a chlorine, will damage the sensor on contact. While it is possible to use the instrument in a non-flammable, non-caustic gases the instrument is not calibrated for these gases and it will not measure airflow accurately.
Give us a call! Our customer service team is happy to discuss your application and find a solution that works for you. We won’t sell you a product that doesn’t meet your needs.
Our sales representatives are here to help you find the right instrument for your application. Fast.
Request a quote today to find the product you need with expert assistance.