Multi-Channel Anemometer – 1550/1560 Series

Multi-channel anemometer for monitoring up to 64 points

Request Quote

Kanomax Multi-Channel Anemometers are research-grade airflow measuring instruments designed for high performance and precision. When coupled with our highly accurate probes this four-channel anemometer provides highly accurate and reliable data readings. It features a LCD display that displays the data from each channel. The Our 1550 & 1560 models house module bays for the connection of up to 24 channels (model 1560) or 64 channels (model 1550) of simultaneous air velocity measurements. Each bay accepts one of five unique modules allowing for a wide variety of custom configurations for air velocity, temperature, and humidity measurement. For a larger system, you can connect up to 5 units in a cascade for up to 320 air velocity channels and transfer the data to your company computer.

More Information

Navigate the tab section below to see this product’s Features & Benefits, Specifications, Resources, and more.

  • 1550/1560 Anemometer is a research-grade instrument designed for high performance precise measurements
  • When coupled with our highly accurate probes this multi-channel anemometer deliver a scalable system
  • The Kanomax 1550 & 1560 house modules bays for the connection of up to 24 channels (model 1560) or 64 channels (model 1550) of simultaneous air velocity measurements
  • Each bay accepts one of five unique modules allowing for a wide variety of custom configurations for air velocity, temperature, and humidity measurement
  • Multiple probes (Air Velocity, Temperature & Humidity) are available
  • For a larger system, you can connect up to 5 units in a cascade for up to 320 air velocity channels and transfer the data to your company computer
  • Both units feature a bright LCD display that reveals the data from each channel
  • Burst mode allows you to output the data of all channels at high speed and and decide which probe to query and send data from
  • Ventilation monitoring for energy efficient building
  • Evaluate cooling efficiency in the electronic device
  • Aerodynamics Research
  • Production Control
  • Product Development

Main Unit and Probe Specifications

Main Unit Specifications
Model15501560
Display Resolution0.01 m/s (@ range of 0 to 9.99m/s)
0.1 m/s (@ 10 m/s or more)
0.1°C (Temperature)
0.1% (Relative Humidity)
Number of Module Slots166
Analog Output0 to 5 V (with optional module)
InterfaceRS-232C
Operation Temperature41 to 104°F (5 to 40°C) with no condensation
Storage Temperature Range14 to 122°F (-10 to 50°C) with no condensation
Dimensions16.9″ x 19.6″ x 5.5″ (430 x 500 x 140 mm)8.9″ x 12.8″ x 5.5″ (226 x 325 x 140mm)
Weight22lbs (10kg)11lbs (5kg)
PowerAC 100V (50/60 Hz)
Warranty1 year
Standard AccessoryMeter, Operation Manual, RS-232C Cable, Power Cord, Fuse

Optional Probe Specifications
Air Velocity
Ranges0.1 to 25.0 m/s
0.1 to 50.0 m/s
Accuracy+/- (3% of READING +/- 0.1) m/s
Operating Temperature Range-4 to 158°F (-20 to 70°C) with no condensation
Storage Temperature Range14 to 122°F (-10 to 50°C) with no condensation
Warranty1 year
Standard AccessoryProbe, Data ROM, NIST Certificate

Model0962-000963-000965-000965-010965-030965-040965-070965-080965-090965-10
Air Velocity Range (m/s)0.1 to 50.00.1 to 50.00.1 to 25.00.1 to 25.00.1 to 25.00.1 to 25.00.1 to 25.00.1 to 25.00.1 to 50.00.1 to 50.0
Airflow DirectivityMonoMonoOmniOmniOmniOmniOmniOmniOmniOmni
Probe TypeRodRodSphericalSphericalMiniatureMiniatureMiniatureMiniatureSphericalSpherical
Air VelocityOOOOOOOOOO
Acclimation Time (sec)1177777777

Air and Temperature Probe Specifications

Air Velocity
Ranges0.1 to 25.0 m/s
0.1 to 50.0 m/s
Accuracy+/- (3% of READING +/- 0.1) m/s
Temperature
Ranges0 to 100 °C
Accuracy+/- 1 °C
Operating Temperature Range-4 to 158°F (-20 to 70°C) with no condensation
Storage Temperature Range14 to 122°F (-10 to 50°C) with no condensation
Warranty1 year
Standard AccessoryProbe, Data ROM, NIST Certificate

Model0962-210963-210965-21
Air Velocity Range (m/s)0.1 to 50.00.1 to 50.00.1 to 25.0
Airflow DirectivityMonoMonoOmni
Probe TypeRodRodSpherical
Air VelocityOOO
Air TemperatureOOO
Acclimation time (sec)117

Air, Temperature, and Relative Humidity Probe Specifications

Air Velocity
Ranges0.1 to 25.0 m/s
0.1 to 50.0 m/s
Accuracy+/- (3% of READING +/- 0.1) m/s
Temperature
Ranges0 to 60 °C
Accuracy+/- 1 °C
Relative Humidity
Ranges5 to 95 %RH
Accuracy+/- 3% (@ 5 to 80%RH)
+/- 5% (@ 80 to 95 %RH)
Operating Temperature Range-4 to 158°F (-20 to 70°C) with no condensation
Storage Temperature Range14 to 122°F (-10 to 50°C) with no condensation
Warranty1 year
Standard AccessoryProbe, Data ROM, NIST Certificate

Model0963-310965-31
Air Velocity Range (m/s)0.1 to 50.00.1 to 25.0
Airflow DirectivityMonoOmni
Probe TypeRodSpherical
Air VelocityOO
Air TemperatureOO
Relative HumidityOO
Acclimation time (sec)17

User Manual

Download

Data Sheet - English

Download

Data Sheet - Espanol

Download

Application Note

Download

Engineering Drawings

Download

Software Manual

Download

  • Uni-Directional Probe (V): Model 0962-00
  • Uni-Directional Probe (V): Model 0963-00
  • Omni-Directional Probe (V): Model 0965-00
  • Omni-Directional Probe (V): Model 0965-01
  • Miniature Omni-Directional Probe (V): Model 0965-03
  • Miniature Omni-Directional Probe (V): Model 0965-04
  • Miniature Omni-Directional Probe (V): Model 0965-07
  • Miniature Omni-Directional Probe (V): Model 0965-08
  • Omni-Directional Probe (V): Model 0965-09
  • Omni-Directional Probe (V): Model 0965-10
  • Uni-Directional Probe (V/T): Model 0962-21
  • Uni-Directional Probe (V/T): Model 0963-21
  • Omni-Directional Probe (V/T): Model 0965-21
  • Omni-Directional Probe (V/T/H): Model 0963-31
  • V/T/H Module: Model 1512
  • V Module: Model 1504
  • V/T Module: Model 1511
  • Analog Module: Model 1510
  • Blank Module Panel: Model 1500
  • AC Adapter: Model 6332-02
  • 11mm Probe Protector: Model 6521-30
  • 4.6mm Probe Protector: Model 1500-03
  • 2M 1-Channel Probe Cable (V): Model 1504-02
  • 5M 1-Channel Probe Cable (V): Model 1504-03
  • 10M 1-Channel Probe Cable (V): Model 1504-04
  • 20M 1-Channel Probe Cable (V): Model 1504-05
  • 30M 1-Channel Probe Cable (V): Model 1504-06
  • DPS for Multi-channel: Model S620-00
How do hot-wire anemometers measure air velocity?

They measure the air speed by calculating how fast the probe sensor is being cooled by the airflow.

Aren't all hot-wire anemometers the same? Why should I buy an Anemomaster Professional anemometer?

The principles behind all hot-wire anemometers may be the same, but the quality varies. Our units are some of the most accurate on the market. This is due to several factors:

1) We calibrate the temperature compensation sensor, as well as the velocity sensor. Other manufacturers only calibrate the velocity sensor.

2) We use special high-quality materials, like our platinum sensors, that increase accuracy.

3) Our manufacturing facility uses not 1, but 4 specialized wind tunnels to test and calibrate our anemometers. These wind tunnels include a low velocity tunnel, high tunnel velocity and a variable temperature wind tunnel.

4) We’ve been making anemometers for over 60 years. During that time we’ve perfected our knowledge and refined our manufacturing process to produce a research-grade instrument.

Does the unit come with an NIST traceable certificate?

Yes, all our instruments come with a calibration certificate.

How often does the unit need to be calibrated?

Annual calibration is recommended to ensure accuracy. However, this can vary based on how often the anemometer is used and the environments it’s used in. Also, some companies have an SOP in place that specifies how often the instrument will need to be serviced. More specifically, regulatory compliance may dictate the calibration interval.

What kinds of airflow can I measure with my Kanomax anemometer?

You can measure clean air between -4 and 158°F (-20 to 70°C) in an environment with no visible condensation. (Please note: the temperature range given is for the probes)

Can I measure airflow in flammable and corrosive gases?

No, these are thermal anemometers that generate heat when in operation; if you expose them to a flammable gas it could cause a fire or explosion. Corrosive or caustic gases, such a chlorine, will damage the sensor on contact. While it is possible to use the instrument in a non-flammable, non-caustic gases the instrument is not calibrated for these gases and it will not measure airflow accurately.

What multi-channel options are available from Kanomax?

We have three multi-channel anemometers: The 1570 is a 4-channel anemometer that just measure air velocity. The 1550 and 1560 have more channels (16 and 6 respectively) and can also measure temperature and relative humidity. These two units can be operated in a cascade configuration where multiple units can be chained together to create more channels.

How do I order a multi-channel system?

These systems are designed for flexibility so you can buy exactly what you need for your specific application. The 4-channel 1570 is easy to order as it requires only the main unit and then whichever probes and cables suit your application. The 1550 and 1560 are a bit more complex as these instruments are composed of the chassis, modules, cables and probes. Each probe must have the correct corresponding module installed in the chassis to plug into. We suggest calling your distributor or Kanomax to get assistance with ordering these systems.

What is included with Models 1550 and 1560?

Data processing software, RS232C cable, power cable and 2 pcs. fuse.

The Climomaster probes are listed as interchangeable, what does that mean?

Give us a call! Our customer service team is happy to discuss your application and find a solution that works for you. We won’t sell you a product that doesn’t meet your needs.

Our sales representatives are here to help you find the right instrument for your application. Fast.

Request a quote today to find the product you need with expert assistance.

Request a Quote Today